Input power: AC 220V soil 10% / 50Hz Measuring range: 10 ~ 100V Voltage Accuracy: 0.2% of reading + 0.2% of range Charging range: 0 ~ 10000ma Charging accuracy: 0.2% of reading + 0.2% of range electric current Discharge range: 0 ^ 20000ma (maximum discharge Power 1400W) Accuracy: 0.2% of reading + 0.2% of range charge Constant voltage cutoff current: minimum 10mA capacity Accuracy: ± 1% o power Discharge power: ≌ 1400W Patrol inspection time: receiving time <2S time Timing range: 0999 hours / work step Data recording interval: ≥ 5S Intermediate machine version: 1.1 series Charging mode: constant current and constant voltage charging Charging cutoff conditions: voltage, current, relative time, overcharge protection Discharge mode: constant current discharge Discharge cutoff conditions: voltage, relative time, over discharge protection Cycle measurement range: 1 "999 times Cycle: single cycle work steps 100 Voltage and current detection sampling: four wire connection Noise: <50dB Database: MySQL database is used to manage test data Communication mode of upper computer: Based on TCP / IP protocol and serial port Data output mode: Excel, TXT, chart Communication interface: network interface Number of channels per cabinet: 12 Case size: w * D * H: 45 * 30 * 17 (CM) Cabinet size: w * D * H: 90 * 60 * 190 (CM)
Parameters
Input power: AC 220V soil 10% / 50Hz Measuring range: 10 ~ 100V Voltage Accuracy: 0.2% of reading + 0.2% of range Charging range: 0 ~ 10000ma Charging accuracy: 0.2% of reading + 0.2% of range electric current Discharge range: 0 ^ 20000ma (maximum discharge Power 1400W) Accuracy: 0.2% of reading + 0.2% of range charge Constant voltage cutoff current: minimum 10mA capacity Accuracy: ± 1% o power Discharge power: ≌ 1400W Patrol inspection time: receiving time <2S time Timing range: 0999 hours / work step Data recording interval: ≥ 5S Intermediate machine version: 1.1 series Charging mode: constant current and constant voltage charging Charging cutoff conditions: voltage, current, relative time, overcharge protection Discharge mode: constant current discharge Discharge cutoff conditions: voltage, relative time, over discharge protection Cycle measurement range: 1 "999 times Cycle: single cycle work steps 100 Voltage and current detection sampling: four wire connection Noise: <50dB Database: MySQL database is used to manage test data Communication mode of upper computer: Based on TCP / IP protocol and serial port Data output mode: Excel, TXT, chart Communication interface: network interface Number of channels per cabinet: 12 Case size: w * D * H: 45 * 30 * 17 (CM) Cabinet size: w * D * H: 90 * 60 * 190 (CM)